Plc controller wholesale manufacturer in China: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. Find extra information on hmi manufacturers.

Response Speed Requirements: PLC is a general controller designed for industrial automation, and the response speed of different grades of PLC can generally meet the needs of its application range. If you wanna use plc across the range, or some functions or signals have special speed requirements, you should carefully consider the response speed of the plc, you can choose a plc with high-speed i/o processing function, or choose a plc with a fast response module and an interrupt input module.

Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.

It is good to choose a brand according to the needing of the customers or the market. But it is not for selecting a brand to decide, or more about to focus on its performance parameters, and to be used the functions achieved. Actually there is an attractive story behind the famous brand. So to choose a brand, try to achieve high practicality, to avoide waste one’s talent on a petty job. For example, Siemens, Mitsubishi, Proface, Panasonic brand…etc with a good performance, but before decision to select them, should consider, how many performance of HMI panel will be used for the project? Whether the cost paid matches the performance used on the project? Discover additional information on https://www.mochuan-drives.com/.

Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).

The Macro instructions of HMI Human Machine Interface are based on C language and the system is developed on Linux. There are multi-types of HMI panel, mainly three types, multi touch capacitive hmi panel, plastic shell enconomic resistive hmi touchscreen panel and metal shell wide-temperature resistive touch screen and small home screen to meet different requirement from application scenarios and market needing. There are rich serial port such as rs485, rs232, rs422, ethernet etc to meet the master and slave to use. Mochuan human machine interface manufacturer suppors the size from 4.3inch to 32inch.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

The Fifth Step: Selecting A Supplier The correct undertanding of a supplier is to be able to provide very stable performance products and after sale and technical service, can do online one-to-one timely guidance and solution. In the face of unforeseen events have the feasibility and flexibility of the program to provide. After all, industrial HMI PLC is a technical product, needing for a manufacturer’s cooperation and support, to make customer worry-free. Maybe you can choose Mochuan Drives. A small try will bring a high value, so why not try?

Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: According to the big data collected by the embedded industrial touch screen plus simple plc, the efficiency of each equipment in the electrical room can be monitored, so that the operation level of the electrical room can be improved and improved based on the evidence.

Human-machine interfaces exist in all areas where human-machine information exchange is involved. A large number of industrial and commercial use, a simple distinction between “input” (Input) and “output” (Output) two, input refers to the operation of machinery or equipment by people, such as handles, switches, doors, instructions (orders) issued or maintenance, and output refers to the machinery or equipment issued by the notice, such as failure, warning, operating instructions tips, etc., a good human-machine interface will Help users more simple, more correct, more rapid operation of machinery, but also to maximize the performance of machinery and extend the service life, and the market refers to the human-machine interface is more narrowly defined in the software user-friendly operating interface.